15. A New Method of Testing Oil-Filled Current Transformers for Explosion-Proofness

15. A New Method of Testing Oil-Filled Current Transformers for Explosion-Proofness

Pakhomov S. N., Reznichenko V. I., Mostipan S. E.

Yangel Yuzhnoye State Design Office, Dnipro, Ukraine

Kosm. teh. Raket. vooruž. 2016 (2); 92-97
 
Language: Russian
Annotation:
The results of tests of high-voltage measuring current transformers TFRM with discharge valves and reinforced porcelain cover, in which transformer oil is used as internal insulation, by means of explosive blasting simulating short circuit inside current transformer, are under consideration.

Full Text(PDF) Content 2016 (2)